The Alarm API allows setting an "alarm clock" for the delivery of a notification at some point in the future.
Required Header
#include <app_alarm.h>
Overview
Mobile devices typically give constant access to information from various sources. Some of this information is best delivered through alarms - the most obvious case is a calendar scheduling application which lets you know when a meeting is about to start. Alarms are certainly better than actively waiting in a loop. They are also better than putting an interface to sleep because they do not block your main UI thread. Use of alarms helps build smooth user experiences and implements unattended data synchronization tasks. If an application is installed after setting the alarm, your alarm is cancelled automatically.
When the alarm is expired, Alarm Manager will turn on LCD to prohibit background jobs. Please make sure background jobs using alarm APIs are not allowed.
There are 3 ways to set an alarm.
FUNCTION | DESCRIPTION |
---|---|
alarm_schedule_once_after_delay() | Sets an alarm to be triggered at specific time once |
alarm_schedule_once_at_date() | Sets an alarm to be triggered after specific delay once |
alarm_schedule_with_recurrence_week_flag() | Sets an alarm to be triggered at specific time with recurrent days of the week(can repeat on days of the week) |
Functions | |
int | alarm_schedule_after_delay (app_control_h app_control, int delay, int period, int *alarm_id) |
Sets an alarm to be triggered after a specific time. | |
int | alarm_schedule_at_date (app_control_h app_control, struct tm *date, int period, int *alarm_id) |
Sets an alarm to be triggered at a specific time. | |
int | alarm_schedule_with_recurrence_week_flag (app_control_h app_control, struct tm *date, int week_flag, int *alarm_id) |
Sets an alarm to be triggered periodically, starting at a specific time. | |
int | alarm_get_scheduled_recurrence_week_flag (int alarm_id, int *week_flag) |
Gets the recurrence days of the week. | |
int | alarm_cancel (int alarm_id) |
Cancels the alarm with the specific alarm ID. | |
int | alarm_cancel_all (void) |
Cancels all scheduled alarms that are registered by the application that calls this API. | |
int | alarm_foreach_registered_alarm (alarm_registered_alarm_cb callback, void *user_data) |
Retrieves the IDs of all registered alarms by invoking a callback once for each scheduled alarm. | |
int | alarm_get_scheduled_date (int alarm_id, struct tm *date) |
Gets the scheduled time from the given alarm ID in C standard time struct. | |
int | alarm_get_scheduled_period (int alarm_id, int *period) |
Gets the period of time between the recurrent alarms. | |
int | alarm_get_current_time (struct tm *date) |
Gets the current system time using C standard time struct. | |
int | alarm_get_app_control (int alarm_id, app_control_h *app_control) |
Gets the app_control to be invoked when the the alarm is triggered. | |
Typedefs | |
typedef bool(* | alarm_registered_alarm_cb )(int alarm_id, void *user_data) |
Called once for each scheduled alarm to get the alarm ID. | |
Defines | |
#define | APP_CONTROL_DATA_ALARM_ID "http://tizen.org/appcontrol/data/alarm_id" |
Definition to app_control extra data : the ID of the alarm registered. |
Define Documentation
#define APP_CONTROL_DATA_ALARM_ID "http://tizen.org/appcontrol/data/alarm_id" |
Definition to app_control extra data : the ID of the alarm registered.
- Since :
- 2.3.1
Typedef Documentation
typedef bool(* alarm_registered_alarm_cb)(int alarm_id, void *user_data) |
Called once for each scheduled alarm to get the alarm ID.
- Since :
- 2.3.1
- Parameters:
-
[in] alarm_id The alarm ID returned when the alarm is scheduled [in] user_data The user data passed from the foreach function
- Returns:
true
to continue with the next iteration of the loop, otherwisefalse
to break out of the loop
- Precondition:
- alarm_foreach_registered_alarm() will invoke this callback to get all the registered alarm IDs.
- See also:
- alarm_foreach_registered_alarm()
Enumeration Type Documentation
enum alarm_error_e |
Enumeration for Alarm Error.
- Since :
- 2.3.1
- Enumerator:
enum alarm_week_flag_e |
Enumeration for Alarm Week Flag, the days of the week.
- Since :
- 2.3.1
Function Documentation
int alarm_cancel | ( | int | alarm_id | ) |
Cancels the alarm with the specific alarm ID.
- Since :
- 2.3.1
- Privilege Level:
- public
- Privilege:
- http://tizen.org/privilege/alarm.set
- Parameters:
-
[in] alarm_id The alarm ID that is cancelled
- Returns:
0
on success, otherwise a negative error value
- Return values:
-
ALARM_ERROR_NONE Successful ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server ALARM_ERROR_PERMISSION_DENIED Permission denied
int alarm_cancel_all | ( | void | ) |
Cancels all scheduled alarms that are registered by the application that calls this API.
- Since :
- 2.3.1
- Privilege Level:
- public
- Privilege:
- http://tizen.org/privilege/alarm.set
- Returns:
0
on success, otherwise a negative error value
- Return values:
-
ALARM_ERROR_NONE Successful ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server ALARM_ERROR_PERMISSION_DENIED Permission denied
int alarm_foreach_registered_alarm | ( | alarm_registered_alarm_cb | callback, |
void * | user_data | ||
) |
Retrieves the IDs of all registered alarms by invoking a callback once for each scheduled alarm.
- Since :
- 2.3.1
- Privilege Level:
- public
- Privilege:
- http://tizen.org/privilege/alarm.get
- Parameters:
-
[in] callback The callback function to invoke [in] user_data The user data to be passed to the callback function
- Returns:
0
on success, otherwise a negative error value
- Return values:
-
ALARM_ERROR_NONE Successful ALARM_ERROR_INVALID_PARAMETER Invalid parameter ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server ALARM_ERROR_PERMISSION_DENIED Permission denied
- Postcondition:
- This function invokes alarm_registered_alarm_cb() repeatedly for each registered alarm.
- See also:
- alarm_registered_alarm_cb()
int alarm_get_app_control | ( | int | alarm_id, |
app_control_h * | app_control | ||
) |
Gets the app_control to be invoked when the the alarm is triggered.
- Since :
- 2.3.1
- Privilege Level:
- public
- Privilege:
- http://tizen.org/privilege/alarm.get
- Remarks:
- The app_control must be released using app_control_destroy().
- Parameters:
-
[in] alarm_id The alarm ID uniquely identifies an alarm [out] app_control The app_control handle to launch when the alarm is triggered
- Returns:
0
on success, otherwise a negative error value
- Return values:
-
ALARM_ERROR_NONE Successful ALARM_ERROR_INVALID_PARAMETER Invalid parameter ALARM_ERROR_OUT_OF_MEMORY Out of memory ALARM_ERROR_PERMISSION_DENIED Permission denied
int alarm_get_current_time | ( | struct tm * | date | ) |
Gets the current system time using C standard time struct.
- Since :
- 2.3.1
- Parameters:
-
[out] date The current system time
- Returns:
0
on success, otherwise a negative error value
- Return values:
-
ALARM_ERROR_NONE Successful ALARM_ERROR_INVALID_PARAMETER Invalid parameter ALARM_ERROR_PERMISSION_DENIED Permission denied
int alarm_get_scheduled_date | ( | int | alarm_id, |
struct tm * | date | ||
) |
Gets the scheduled time from the given alarm ID in C standard time struct.
- Since :
- 2.3.1
- Privilege Level:
- public
- Privilege:
- http://tizen.org/privilege/alarm.get
- Parameters:
-
[in] alarm_id The alarm ID returned when the alarm is scheduled [out] date The time value of the next alarm event
- Returns:
0
on success, otherwise a negative error value
- Return values:
-
ALARM_ERROR_NONE Successful ALARM_ERROR_INVALID_PARAMETER Invalid parameter ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server ALARM_ERROR_PERMISSION_DENIED Permission denied
int alarm_get_scheduled_period | ( | int | alarm_id, |
int * | period | ||
) |
Gets the period of time between the recurrent alarms.
- Since :
- 2.3.1
- Privilege Level:
- public
- Privilege:
- http://tizen.org/privilege/alarm.get
- Remarks:
- If the given alarm_id is not obtained by using the alarm_get_scheduled_date() or alarm_schedule_after_delay() function, an error (error code ALARM_ERROR_INVALID_PARAMETER) will occur.
- Parameters:
-
[in] alarm_id The alarm ID returned when the alarm is scheduled [out] period The period of time between recurrent alarms in seconds
- Returns:
0
on success, otherwise a negative error value
- Return values:
-
ALARM_ERROR_NONE Successful ALARM_ERROR_INVALID_PARAMETER Invalid parameter ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server ALARM_ERROR_PERMISSION_DENIED Permission denied
int alarm_get_scheduled_recurrence_week_flag | ( | int | alarm_id, |
int * | week_flag | ||
) |
Gets the recurrence days of the week.
- Since :
- 2.3.1
- Privilege Level:
- public
- Privilege:
- http://tizen.org/privilege/alarm.get
- Remarks:
- If the given alarm_id is not obtained by using the alarm_schedule_with_recurrence_week_flag() function, an error (error code ALARM_ERROR_INVALID_PARAMETER) will occur because this alarm is scheduled with no recurrence. If the operation of app_control is not specified, APP_CONTROL_OPERATION_DEFAULT is used for the launch request. If the operation of app_control is APP_CONTROL_OPERATION_DEFAULT, the package information is mandatory to explicitly launch the application.
- Parameters:
-
[in] alarm_id The alarm ID returned when the alarm is scheduled [out] week_flag The recurrence days of the week, week_flag may be a combination of days, like ALARM_WEEK_FLAG_TUESDAY | ALARM_WEEK_FLAG_FRIDAY
- Returns:
0
on success, otherwise a negative error value
- Return values:
-
ALARM_ERROR_NONE Successful ALARM_ERROR_INVALID_PARAMETER Invalid parameter ALARM_ERROR_PERMISSION_DENIED Permission denied
int alarm_schedule_after_delay | ( | app_control_h | app_control, |
int | delay, | ||
int | period, | ||
int * | alarm_id | ||
) |
Sets an alarm to be triggered after a specific time.
The alarm will first go off delay seconds later and then will go off every certain amount of time defined using period seconds. If period is bigger than 0
, the alarm will be scheduled after the period time. If period is set to 0
, the alarm will go off just once without repetition. To cancel the alarm, call alarm_cancel() with alarm_id.
- Since :
- 2.3.1
- Privilege Level:
- public
- Privilege:
- http://tizen.org/privilege/alarm.set
- Remarks:
- If the application is uninstalled after setting an alarm, the alarm is cancelled automatically.
- Parameters:
-
[in] app_control The destination app_control to perform a specific task when the alarm is triggered [in] delay The amount of time before the first execution (in seconds) [in] period The amount of time between subsequent alarms (in seconds) [out] alarm_id The alarm ID that uniquely identifies an alarm
- Returns:
0
on success, otherwise a negative error value
- Return values:
-
ALARM_ERROR_NONE Successful ALARM_ERROR_INVALID_PARAMETER Invalid parameter ALARM_ERROR_INVALID_TIME Triggered time is invalid ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server ALARM_ERROR_PERMISSION_DENIED Permission denied
int alarm_schedule_at_date | ( | app_control_h | app_control, |
struct tm * | date, | ||
int | period, | ||
int * | alarm_id | ||
) |
Sets an alarm to be triggered at a specific time.
The date describes the time of the first occurrence. If period is bigger than 0
, the alarm will be scheduled after the period time. If period is set to 0
, the alarm will go off just once without repetition. To cancel the alarm, call alarm_cancel() with alarm_id.
- Since :
- 2.3.1
- Privilege Level:
- public
- Privilege:
- http://tizen.org/privilege/alarm.set
- Remarks:
- If application is uninstalled after setting an alarm, the alarm is cancelled automatically. If the operation of app_control is not specified, APP_CONTROL_OPERATION_DEFAULT is used for the launch request. If the operation of app_control is APP_CONTROL_OPERATION_DEFAULT, the package information is mandatory to explicitly launch the application.
- Parameters:
-
[in] app_control The destination app_control to perform specific work when the alarm is triggered [in] date The first active alarm time [in] period The amount of time between subsequent alarms(in second) [out] alarm_id The alarm ID that uniquely identifies an alarm
- Returns:
0
on success, otherwise a negative error value
- Return values:
-
ALARM_ERROR_NONE Successful ALARM_ERROR_INVALID_PARAMETER Invalid parameter ALARM_ERROR_INVALID_DATE Triggered date is invalid ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server ALARM_ERROR_PERMISSION_DENIED Permission denied
int alarm_schedule_with_recurrence_week_flag | ( | app_control_h | app_control, |
struct tm * | date, | ||
int | week_flag, | ||
int * | alarm_id | ||
) |
Sets an alarm to be triggered periodically, starting at a specific time.
The date describes the time of the first occurrence. week_flag is the repeat value of the days of the week. If week_flag is ALARM_WEEK_FLAG_TUESDAY, the alarm will repeat every Tuesday at a specific time. To cancel the alarm, call alarm_cancel() with alarm_id.
- Since :
- 2.3.1
- Privilege Level:
- public
- Privilege:
- http://tizen.org/privilege/alarm.set
- Remarks:
- If the application is uninstalled after setting an alarm, the alarm is cancelled automatically. If the operation of app_control is not specified, APP_CONTROL_OPERATION_DEFAULT is used for the launch request. If the operation of app_control is APP_CONTROL_OPERATION_DEFAULT, the package information is mandatory to explicitly launch the application.
- Parameters:
-
[in] app_control The destination app_control to perform specific work when the alarm is triggered [in] date The first active alarm time [in] week_flag The day of the week, week_flag may be a combination of days, like ALARM_WEEK_FLAG_TUESDAY | ALARM_WEEK_FLAG_FRIDAY [out] alarm_id The alarm ID that uniquely identifies an alarm
- Returns:
0
on success, otherwise a negative error value
- Return values:
-
ALARM_ERROR_NONE Successful ALARM_ERROR_INVALID_PARAMETER Invalid parameter ALARM_ERROR_INVALID_DATE Triggered date is invalid ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server ALARM_ERROR_PERMISSION_DENIED Permission denied